A normalization procedure for pulse thermographic nondestructive evaluation

Research output: Contribution to journalArticlepeer-review

Abstract

Pulse thermographic nondestructive evaluation (TNDE) technique can be used to estimate defect dimensions, and in particular the depth at which the defect is located. Numerical models of this procedure can aid in the interpretation of experimental results. However, the thermophysical properties of the test object as well as the amount of energy absorbed during this process are not readily available for such models. This paper presents an extension of the thermographic signal reconstruction (TSR) procedure in which the temperature and the time scales are respectively normalized with equilibrium temperature and the break time. In the normalized form these profiles are independent of material properties and instrumentation settings. Thus in the normalized format, experimental results can be readily compared with numerically generated thermographic results. The defect depth can also be easily obtained as a fraction of plate thickness from this plot.
Original languageEnglish
Pages (from-to)14-23
Number of pages10
JournalNDT and E International
Volume83
Issue numberTBD
DOIs
StatePublished - Oct 1 2016

Keywords

  • Finite Element Analysis
  • Flaw detection
  • Nondestructive evaluation
  • Pulse thermographic technique
  • TSR technique
  • Thermography

Fingerprint

Dive into the research topics of 'A normalization procedure for pulse thermographic nondestructive evaluation'. Together they form a unique fingerprint.

Cite this