Enhancement in blood-tumor barrier permeability and delivery of liposomal doxorubicin using focused ultrasound and microbubbles: Evaluation during tumor progression in a rat glioma model

  • Muna Aryal
  • , Juyoung Park
  • , Natalia Vykhodtseva
  • , Yong-Zhi Zhang
  • , Nathan McDannold
  • Boston College
  • Harvard Medical School
  • Daegu-Gyeongbuk Medical Innovation Foundation

Research output: Contribution to journalArticlepeer-review

100 Scopus citations

Abstract

Effective drug delivery to brain tumors is often challenging because of the heterogeneous permeability of the 'blood tumor barrier' (BTB) along with other factors such as increased interstitial pressure and drug efflux pumps. Focused ultrasound (FUS) combined with microbubbles can enhance the permeability of the BTB in brain tumors, as well as the blood-brain barrier in the surrounding tissue. In this study, dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) was used to characterize the FUS-induced permeability changes of the BTB in a rat glioma model at different times after implantation. 9L gliosarcoma cells were implanted in both hemispheres in male rats. At day 9, 14, or 17 days after implantation, FUS-induced BTB disruption using 690 kHz ultrasound and definity microbubbles was performed in one tumor in each animal. Before FUS, liposomal doxorubicin was administered at a dose of 5.67 mg kg-1. This chemotherapy agent was previously shown to improve survival in animal glioma models. The transfer coefficient Ktrans describing extravasation of the MRI contrast agent Gd-DTPA was measured via DCE-MRI before and after sonication. We found that tumor doxorubicin concentrations increased monotonically (823 ± 600, 1817 ± 732 and 2432 ± 448 ng g-1) in the control tumors at 9, 14 and 17 d. With FUS-induced BTB disruption, the doxorubicin concentrations were enhanced significantly (P<0.05, P<0.01, and P<0.0001 at days 9, 14, and 17, respectively) and were greater than the control tumors by a factor of two or more (2222 ± 784, 3687 ± 796 and 5658 ± 821 ng g-1) regardless of the stage of tumor growth. The transfer coefficient Ktrans was significantly (P<0.05) enhanced compared to control tumors only at day 9 but not at day 14 or 17. These results suggest that FUS-induced enhancements in tumor drug delivery are relatively consistent over time, at least in this tumor model. These results are encouraging for the use of large drug carriers, as they suggest that even large/late-stage tumors can benefit from FUS-induced drug enhancement. Corresponding enhancements in Ktrans were found to be variable in large/late-stage tumors and not significantly different than controls, perhaps reflecting the size mismatch between the liposomal drug (∼100 nm) and Gd-DTPA (molecular weight: 938 Da; hydrodynamic diameter: ≃2 nm). It may be necessary to use a larger MRI contrast agent to effectively evaluate the sonication-induced enhanced permeabilization in large/late-stage tumors when a large drug carrier such as a liposome is used.
Original languageEnglish
Pages (from-to)2511-2527
Number of pages17
JournalPhysics in Medicine and Biology
Volume60
Issue number6
DOIs
StatePublished - Mar 21 2015

Keywords

  • blood brain barrier
  • blood tumor barrier
  • brain drug delivery
  • dynamic contrast enhanced RI
  • focused ultrasound
  • pharmacokinetic model

Fingerprint

Dive into the research topics of 'Enhancement in blood-tumor barrier permeability and delivery of liposomal doxorubicin using focused ultrasound and microbubbles: Evaluation during tumor progression in a rat glioma model'. Together they form a unique fingerprint.

Cite this