Evaluation of Fire Effects on Reinforced Concrete Columns Using Finite Element Method

Research output: Contribution to journalArticle

Abstract

In this paper, four different Reinforced Concrete (RC) columns are analyzed with Finite Element (FE) ABAQUS software and validated experimentally. One of the RC columns, the control specimen, is subjected to only compressive force applied at both ends of the column, while the other three models were loaded under both compressive force and fire load. The temperature is applied to reach up to 600 Celsius Degree for the period of 10, 15 and 20 min. The load-displacement diagrams were constructed. Results showed good correlations between experimental and FE analysis. Moreover, results showed reduction in load capacity as duration of fire load increases.
Original languageEnglish
Pages (from-to)Pages 227-235
JournalAm. J. Eng. Applied Sci
VolumeVol. 12
Issue number2
StatePublished - 2019

Fingerprint

Dive into the research topics of 'Evaluation of Fire Effects on Reinforced Concrete Columns Using Finite Element Method'. Together they form a unique fingerprint.