Skip to main navigation Skip to search Skip to main content

OASIS-Net: An Obstetric Adversarial Semi-Supervised Image Segmentation Network for Cervical and Fetal Head Ultrasound Imaging

  • Minh Huu Nhat Le
  • , Tran Quoc Khanh Le
  • , Thanh-Huy Nguyen
  • , Dang Nguyen
  • , Hien Quang Nguyen
  • , Nhi Huu Hanh Le
  • , Kien Dang Nguyen
  • , Hien Quang Kha
  • , Phat Ky Nguyen
  • , Hoai Huu Le
  • , Han Hong Huynh
  • , Dang-Manh Ho
  • , Thanh-Minh Nguyen
  • , Quan Nguyen
  • , Min Xu
  • , Phat K. Huynh
  • , Nguyen Quoc Khanh Le
  • College of Medicine
  • VNUHCM - University of Information Technology
  • North Carolina Agricultural and Technical State University
  • School of Computer Science
  • Harvard School of Public Health
  • Montefiore Medical Center
  • Thai Binh University of Medicine and Pharmacy
  • Taipei Medical University
  • FPT University
  • Telecommunications Institute of Technology
  • Industrial and systems engineering with North Carolina A&T State University
  • Taipei Medical University Hospital

Research output: Contribution to journal › Article › peer-review

1 Scopus citations

Abstract

Accurate obstetric ultrasound segmentation is hampered by speckle noise and scarce annotations. We propose OASIS-Net, a dual-space adversarial semi-supervised framework that trains a single DeepLabV3+ backbone by minimizing one unified consistency loss. The loss couples input-space adversaries (iterative FGSM with K=3 steps, =4/255) and weight-space gradient-aligned perturbations (DGAP, weight scale =0.5) whose influence grows with a sigmoid ramp (Tramp=20, α =1.0). Pseudo-labels are accepted with a confidence threshold of 0.95 and the unlabeled loss weight is 1.0. We evaluate OASIS-Net on two public obstetric benchmarks: FUGC (50 labeled, 450 unlabeled) and PSFH (5,101 frames, 70% unlabeled). Using 20% of labels, the method attains Dice = 96.53% and HD95 = 3.86 px on FUGC, and Dice = 97.16% and HD95 = 2.34 px on PSFH. Ablation shows that removing either perturbation stream reduces Dice by up to 1.8 percentage points. The trained model runs at 18.96 frames s-1 on a single RTX 4060 Ti and produces high-precision masks that enable automated cervical-length and angle-of-progression measurements for objective obstetric screening and intrapartum monitoring. These results demonstrate that jointly enforcing input- and parameter-space adversarial consistency yields a label-efficient, robust solution for obstetric ultrasound segmentation and supports real-time clinical use.
Original languageEnglish
JournalIEEE Journal of Biomedical and Health Informatics
Issue numberIssue
DOIs
StateAccepted/In press - Jan 1 2025

Keywords

  • Adversarial consistency learning
  • cervical length
  • dual-space perturbation
  • gradient-aligned weight noise
  • obstetric ultrasound
  • pixel-space attacks
  • semi-supervised segmentation
  • transperineal ultrasound
  • transvaginal ultrasound

Fingerprint

Dive into the research topics of 'OASIS-Net: An Obstetric Adversarial Semi-Supervised Image Segmentation Network for Cervical and Fetal Head Ultrasound Imaging'. Together they form a unique fingerprint.

Cite this