TY - JOUR
T1 - Spray cooling with ammonia on microstructured surfaces: Performance enhancement and hysteresis effect
AU - Bostanci, Huseyin
AU - Rini, Daniel P.
AU - Kizito, John P
AU - Chow, Louis C.
PY - 2009/7/1
Y1 - 2009/7/1
N2 - Experiments were performed to investigate spray cooling on microstructured surfaces. Surface modification techniques were utilized to obtain microscale indentations and protrusions on the heater surfaces. A smooth surface was also tested to have baseline data for comparison. Tests were conducted in a closed loop system with ammonia using RTI's vapor atomized spray nozzles. Thick film resistors, simulating heat source, were mounted onto 1×2 cm2 heaters, and heat fluxes up to 500 W/cm2 (well below critical heat flux limit) were removed. Two nozzles each spraying 1 cm2 of the heater area used 96 ml/cm2 min (9.7 gal/ in.2 h) liquid and 13.8 ml/cm2 s (11.3 ft3 / in.2 h) vapor flow rate with only 48 kPa (7 psi) pressure drop. Comparison of cooling curves in the form of surface superheat (ΔTsat=Tsurf-Tsat) versus heat flux in the heating-up and coolingdown modes (for increasing and decreasing heat flux conditions) demonstrated substantial performance enhancement for both microstructured surfaces over smooth surface. At 500 W/cm2, the increases in the heat transfer coefficient for microstructured surfaces with protrusions and indentations were 112% and 49% over smooth surface, respectively. Moreover, results showed that smooth surface gives nearly identical cooling curves in the heating-up and cooling-down modes, while microstructured surfaces experience a hysteresis phenomenon depending on the surface roughness level and yields lower surface superheat in the cooling-down mode, compared with the heating-up mode, at a given heat flux. Microstructured surface with protrusions was further tested using two approaches to gain better understanding on hysteresis. Data indicated that microstructured surface helps retain the established three-phase contact lines, the regions where solid, liquid, and vapor phases meet, resulting in consistent cooling curve and hysteresis effect at varying heat flux conditions (as low as 25 W/cm2 for the present work). Data also confirmed a direct connection between hysteresis and thermal history of the heater. Copyright © 2009 by ASME.
AB - Experiments were performed to investigate spray cooling on microstructured surfaces. Surface modification techniques were utilized to obtain microscale indentations and protrusions on the heater surfaces. A smooth surface was also tested to have baseline data for comparison. Tests were conducted in a closed loop system with ammonia using RTI's vapor atomized spray nozzles. Thick film resistors, simulating heat source, were mounted onto 1×2 cm2 heaters, and heat fluxes up to 500 W/cm2 (well below critical heat flux limit) were removed. Two nozzles each spraying 1 cm2 of the heater area used 96 ml/cm2 min (9.7 gal/ in.2 h) liquid and 13.8 ml/cm2 s (11.3 ft3 / in.2 h) vapor flow rate with only 48 kPa (7 psi) pressure drop. Comparison of cooling curves in the form of surface superheat (ΔTsat=Tsurf-Tsat) versus heat flux in the heating-up and coolingdown modes (for increasing and decreasing heat flux conditions) demonstrated substantial performance enhancement for both microstructured surfaces over smooth surface. At 500 W/cm2, the increases in the heat transfer coefficient for microstructured surfaces with protrusions and indentations were 112% and 49% over smooth surface, respectively. Moreover, results showed that smooth surface gives nearly identical cooling curves in the heating-up and cooling-down modes, while microstructured surfaces experience a hysteresis phenomenon depending on the surface roughness level and yields lower surface superheat in the cooling-down mode, compared with the heating-up mode, at a given heat flux. Microstructured surface with protrusions was further tested using two approaches to gain better understanding on hysteresis. Data indicated that microstructured surface helps retain the established three-phase contact lines, the regions where solid, liquid, and vapor phases meet, resulting in consistent cooling curve and hysteresis effect at varying heat flux conditions (as low as 25 W/cm2 for the present work). Data also confirmed a direct connection between hysteresis and thermal history of the heater. Copyright © 2009 by ASME.
KW - Electronics cooling
KW - Enhanced surfaces
KW - Heat transfer
KW - Hysteresis
KW - Thermal management
KW - Two-phase
UR - https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77955248294&origin=inward
UR - https://www.scopus.com/inward/citedby.uri?partnerID=HzOxMe3b&scp=77955248294&origin=inward
U2 - 10.1115/1.3089553
DO - 10.1115/1.3089553
M3 - Article
SN - 0022-1481
VL - 131
SP - 1
EP - 9
JO - Journal of Heat Transfer
JF - Journal of Heat Transfer
IS - 7
ER -